| Model | LT RF6 |
| Heat zone numbers | 6 zones(Up3, Down3) |
| Heat method | Hot wind |
| Cooling zone numbers | Two natural air cooling |
| Length of heating zone | 1060mm |
| Width of net belt | 300mm |
| PCB size | 280mm |
| Height of net belt | 900±20mm |
| Transport speed of net belt | 160~1350mm/min(Analog quantity adjusting) |
| Transport direction of net belt | Left to right( right to left) |
| Starting power | 9KW |
| Working power | 3KW |
| Input supply power | Three-phase five-wire 380±10% 50HZ |
| Heat up time | About 20 mins |
| Time of passing through the machine | 3.5 to 5.5 mins |
| Range of temperature control | Indoor temperature to 400 degrees |
| Method of temperature control | PID close cycle control |
| Net weight | 215kg |
| Outline size | 2100x680x1200mm |